Electrical Door Lock SV601
Product information "Electrical Door Lock SV601"
Installation in the door frame (no moving cable transitions)
Solid steel bolts D = 17mm
moves out 17mm
tested up to 1000kg door pressure
Quiescent current (door is open on power failure)
for 12V DC voltage ("red" and "brown")
Suitable for permanently controlled door open
Function: opens via make contact ("Orange" versus "brown")
Current consumption at 30mA opening
Stand-by 120mA
Dimensions Boltwork: 100x25x30mm
Dimensions striking plate: 260x30x39mm
including feedback contact for surveillance or alarm system
("Blue", "green" and "white")
including counterpart recognition (bar closes again when the door was closed)
When permission is unlocked and the door can be opened.
Emergency opening always mechanically possible (internal rotary knob, outer cylinder key)
Scope of supply see photo:
- El. locking
- Counterpart
- aperture
- Holders for flush mounting
- Cylinders including rotary knob and 5 key
- Covers and rosettes
- Screws